Lenze 9400 Uživatelský manuál Strana 537

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 954
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 536
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 537
11 Basic drive functions
11.12 Brake control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.12.3 Mode 0: Brake control is switched off
If the mode 0 is selected in C02580, the brake control is switched off.
If a motor brake control module is available, it will not be triggered.
The brake monitoring function is not active.
A potential fault reported by the brake control is reset automatically.
The output signals of the system block LS_Brake are reset:
BRK_dnState = 0
BRK_bReleaseBrakeOut = FALSE
BRK_bBrakeReleased = FALSE
BRK_bError = FALSE
Note!
In the Lenze setting, the mode 0 is preset to get into a safe state after the mains is
switched on.
Zobrazit stránku 536
1 2 ... 532 533 534 535 536 537 538 539 540 541 542 ... 953 954

Komentáře k této Příručce

Žádné komentáře