14 Parameter reference
14.2 Parameter list | C01191
836
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01191
C01192
C01193
C01194
Parameter | Name:
C01191 | Spec. charact.: temperature
Data type: UNSIGNED_32
Index: 23384
d
= 5B58
h
The special thermal sensor characteristic is selected by setting C01190="1"
Motor temperature monitoring
Setting range (min. value | unit | max. value)
0 °C 255
Subcodes Lenze setting Info
C01191/1 25 °C Value 1 for spec. thermal sensor characteristic
C01191/2 150 °C Value 2 for spec. thermal sensor characteristic
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C01192 | Spec. characteristic: resistance
Data type: UNSIGNED_32
Index: 23383
d
= 5B57
h
The special thermal sensor characteristic is selected by setting C01190="1"
Motor temperature monitoring
Setting range (min. value | unit | max. value)
0 Ohm 30000
Subcodes Lenze setting Info
C01192/1 1000 Ohm Value 1 for spec. thermal sensor characteristic
C01192/2 2225 Ohm Value 2 for spec. thermal sensor characteristic
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C01193 | Motor temp. feedback system
Data type: UNSIGNED_16
Index: 23382
d
= 5B56
h
Selection of feedback system for motor temperature detection.
Motor temperature monitoring
Selection list (Lenze setting printed in bold)
0 Speed feedback
1X7 (Input Resolver)
2X8 (Input Encoder)
3 Reserved
4 Reserved
5 X7 and X8 parallel
Read access Write access CINH PLC STOP No transfer Scaling factor: 1
Parameter | Name:
C01194 | Motor operating temperature
Data type: INTEGER_32
Index: 23381
d
= 5B55
h
Setting range (min. value | unit | max. value) Lenze setting
1 °C 200 140 °C
Read access Write access CINH PLC STOP No transfer Scaling factor: 1