Lenze 9400 Uživatelský manuál Strana 437

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 954
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 436
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06 437
11 Basic drive functions
11.6 Homing
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 13: negative direction to limit switch
Procedure:
1. Movement in negative direction with profile data set 1.
2. Positive edge of the travel range limit switch sets reference.
3. Absolute positioning to target position (C02643
) with profile data set 2 (if C02641 ="0").
Negative travel range limit switch
Note!
The load machine can also leave the travel range limit switch. There follows a return to
the home position that was set with the positive edge of the travel range limit switch.
It is possible that, as a result, the machine will remain on an operated limit switch.
Therefore it is recommended to set a target position (C02643
) that is unequal to the
home position (C02642
) to release the activated limit switch again.
1
0
Zobrazit stránku 436
1 2 ... 432 433 434 435 436 437 438 439 440 441 442 ... 953 954

Komentáře k této Příručce

Žádné komentáře