11 Basic drive functions
11.11 Limiter
516
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Priorisation of the limited speeds
The following applies to software versions lower than V3.0:
If several limited speeds are requested at the same time, the parameters of the limited speed
with the lowest number are used, i.e. the "Limited speed 1" has the highest priority.
The following applies from software version V3.0:
If several limited speeds are requested at the same time, the lowest speed with the greatest
deceleration and the lowest S-ramp time is approached from the parameters of the requested
limited speeds.
11.11.2.7 Limited increment for manual jog
Via C02713 the maximum permissible distance (limited increment) for the basic function "Manual
jog" can be set.
The request "Limited increment" is effected via the input LIM_dwControl, generally by the
control word of the safety module. If no safety module is available, the control word for the
input LIM_dwControl can also be generated by means of an inverter.
•In C02714
the maximum permissible distance in [increments] is displayed.